Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(338)
(589)
(599)
(55)
(234)
(1006)
(690)
(2183)
(117)
(95207)
(63)
(575)
(124)
(33)
(21)
(20)
(95391)
(3)
(17)
(1)
(374)
(322)
(6938)
(241)
(21)
(6)
(1667)
(17)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(27)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(33)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • BSI
    BS EN ISO 80601-2-79:2024 Medical electrical equipment - Particular requirements for basic safety and essential performance of ventilatory support equipment for ventilatory impairment
    Edition: 2024
    $557.44
    / user per year

Description of BS EN ISO 80601-2-79:2024 2024

NOTE 1       There is guidance or rationale for this subclause contained in Clause AA.2. This document applies to the basic safety and essential performance of ventilatory support equipment, as defined in 201.3.302, for ventilatory impairment, as defined in 201.3.300, hereafter also referred to as ME equipment, in combination with its accessories: —    intended for use in the home healthcare environment; NOTE 2       In the home healthcare environment, the supply mains driving the ventilatory support equipment is often not reliable. NOTE 3       Such ventilatory support equipment can also be used in professional health care facilities. —    intended for use by a lay operator; —    intended for use with patients who have ventilatory impairment, the most fragile of these patients, would not likely experience injury with the loss of this artificial ventilation; and —    not intended for patients who are dependent on artificial ventilation for their immediate life support. EXAMPLE 1        Patients with mild to moderate chronic obstructive pulmonary disease (COPD). Ventilatory support equipment is not considered to use a physiologic closed-loop control system unless it uses a physiological patient variable to adjust the artificial ventilation therapy settings. This document is also applicable to those accessories intended by their manufacturer to be connected to the breathing system of ventilatory support equipment for ventilatory impairment, where the characteristics of those accessories can affect the basic safety or essential performance of the ventilatory support equipment for ventilatory impairment. EXAMPLE 2        Breathing sets, connectors, water traps, expiratory valve, humidifier, breathing system filter, external electrical power source, distributed alarm system. If a clause or subclause is specifically intended to be applicable to ME equipment only, or to ME systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME equipment and to ME systems, as relevant. Hazards inherent in the intended physiological function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this document except in IEC 60601?1:2005+AMD1:2012+AMD2:2020, 7.2.13 and 8.4.1. NOTE 4       Additional information can be found in IEC 60601?1:2005+AMD1:2012+AMD2:2020, 4.2. NOTE 5       See ISO/TR 21954 for guidance on the selection of the appropriate ventilator for a given patient.  This document does not specify the requirements for: —    ventilators or accessories for ventilator-dependent patients intended for critical care applications, which are given in ISO 80601?2?12; —    ventilators or accessories intended for anaesthetic applications, which are given in ISO 80601?2?13; —    ventilators or accessories intended for the emergency medical services environment, which are given in ISO 80601?2?84; —    ventilators or accessories intended for ventilator-dependent patients in the home healthcare environment, which are given in ISO 80601?2?72; —    ventilatory support equipment or accessories intended for ventilatory insufficiency, which are given in ISO 80601?2?80; —    sleep apnoea therapy ME equipment, which are given in ISO 80601?2?70; —    high-frequency jet ventilators (HFJVs), which are given in ISO 80601?2?87; —    high-frequency oscillatory ventilators (HFOVs); —    respiratory high flow equipment, which are given in

About BSI

BSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses.

X