FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of PD CLC/TS 50131-5-1:2021 2021This document applies to interconnections between intrusion and hold-up alarm system components using specific or non-specific wired interconnections (e.g. between SPT and CIE). The interconnected components are located within the supervised premises, or mounted on the outside of the supervised premises (e.g. external warning devices). This document does not apply to interconnections between components located within the same enclosure, or to interconnections between parts of an I&HAS component if covered by the relevant product standard. This document does not define the physical requirements of the interconnection media. This document is expected to be used in conjunction with the other parts of the EN 50131 series that define the functional requirements of the equipment regardless of the interconnection technique used. Where monitoring of the functionality of the interconnections is undertaken by an interconnected component, this is defined in the relevant product standard in the EN 50131 series. If a component standard indicates that an interconnection will be monitored, then this document determines the monitored conditions applicable to the interconnection. NOTE 1 For example, if there is no requirement in a detector standard to monitor a remote indication of detection input, this document does not apply to that particular interconnection. Requirements for the monitoring of the functionality of power connections between I&HAS components are defined in the relevant product standard and are not included within this document. This document defines the terms used in the field of intrusion and hold-up alarm equipment using such interconnections and includes the requirements relevant to the equipment interfaces. Wired interconnection media can include metallic single stranded insulated cable, metallic multi-stranded insulated cable, and fibre optic cable. These cables can comprise single or multiple cores. NOTE 2 Interconnections using RF techniques (i.e. wire free interconnections) are dealt with by EN 50131 5 3.
About BSIBSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses. |
GROUPS
|