Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Filters:
FORMAT
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(338)
(589)
(599)
(55)
(234)
(1006)
(690)
(2161)
(117)
(94958)
(58)
(575)
(124)
(33)
(21)
(20)
(95391)
(3)
(17)
(1)
(374)
(319)
(6938)
(241)
(21)
(6)
(1667)
(17)
(19)
(28)
(4)
 
(6)
(7)
(115)
(3)
(57)
(5)
(5)
(1)
(1)
(2)
(25)
(27)
(27)
(13)
(61)
(24)
(22)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(33)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • BSI
    PD IEC TS 63019:2019 Photovoltaic power systems (PVPS). Information model for availability
    Edition: 2019
    $569.57
    / user per year

Description of PD IEC TS 63019:2019 2019

A common basis of understanding results from defined metrics that can be useful to the stakeholders, populated by data collected in the operation of the PVPS:

  1. To provide a standarized approach to characterize availablity and unavailablity for a PVPS.

  2. To provide standard methodologies for determining the appropriate forms of availability of the PVPS during varying time periods, including real-time capability assessment or longer, for reporting availablity metrics to stakeholders.

Table 1 – Stakeholder roles and objectives for reliability and maintenance data

Roles Objective
Owner Decision support for investments
Operator Reporting performance indicators
Determining availability and weaknesses
Identifying maintenance strategies
Service provider Maintenance optimization
Optimizing keeping stock of spare parts
Original equipment manufacturers/supplier Design optimization
Financier/insurer Risk assessment
Grid operator Highly reliable and stable bulk power system

Source: International Energy Agency (IEA)

This document provides a framework from which the availability metrics of a PVPS can be derived and reported. It describes how data are categorized and defines generic information categories to which time can be assigned for a PVPS considering internal and external conditions based on fraction of time, system health, and condition by specifying the following:

  • generic information categories of a PVPS considering availability and production.

  • information category priority to discriminate between concurrent categories.

  • entry and exit point for each information category to allocate designation of time.

The PVPS comprises all photovoltaic (PV) modules, inverters, DC and AC collection systems, grid interconnection equipment, the site, its infrastructure, and all functional service elements. This is further explained in 6.3 and 6.4.

Formulas in this document provide normative guidance for standardization. Beyond that, it is not the intention of this document to specify exactly how other undefined, time-based availability metrics shall be calculated. The annexes are examples and guiding principles for developing methods for calculation and estimation of availability metrics, subject to the knowledge and concurrence for use by the involved stakeholders. Estimates and calculations also have recommendations on how they are to be used as part of the informative function.

It is not within the scope of this document to determine the method of information acquisition. Relevant IEC documents on data collection and information acquisition are included in the following normative references. IEC 61724-1 has requirements and IEC TS 61724-3:2016, 6.2.5, specifically identifies measured data on this topic.

Data generated during the operation of a PVPS are valuable, establishing who owns the monitoring data and who will have access to the data and for what purpose should be established. Different stakeholders will have different needs, as summarized in Table 1 (IEA). In Annex E, the monitoring systems are addressed in greater detail.

Availability metrics cannot be derived without important outage information. Questions can require the PVPS operation to properly collect the requisite data, such as what equipment or portion of the plant is failing, how long, how often, and how much energy is being lost and categorized by the information model. Asset management questions include the source of the outage (i.e., Whose clock is it on? Was the outage due to internal or external forces? What power and energy was generated? And, what was expected?).