FORMAT
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Content Description Per NFPA's requirements, when purchasing NFPA 2021 Standards and/or 2020 NFPA 70 (NEC), you must subscribe to at least one more NFPA Standard to complete your purchase. In order to fulfill this requirement, we automatically add 2019 NFPA 900 to your cart. This title may be removed during checkout if you choose to add a different NFPA standard to your cart, and pricing will be recalculated accordingly.
Updates in the 2016 NFPA 13: Standard for the Installation of Sprinkler Systems help designers, engineers, contractors, and installers develop the best fire sprinkler defense for any occupancy. Fire protection challenges have changed along with construction materials and types of storage. Get equipped for today’s hazards by getting up-to-code with the new industry standard for the automatic sprinkler system design, installation, and acceptance testing; hanging and bracing systems; underground piping; and seismic protection. Revisions to commodity classification tables in the 2016 NFPA 13 present the most significant update to the tables in over 30 years. Updated classification tables in Chapter 5 Annex based on today’s materials help sprinkler system designers avoid common errors in classifying commodities. The new tables improve accuracy and reduce the risk for mistakes that could prove catastrophic in a fire. A task group addressed the costly problem of corrosion in piping. In a major change that impacts installers, the 2016 NFPA 13 adds a new requirement that a single air vent be installed for each wet sprinkler system to help reduce potential corrosion activity due to trapped air. A task group concluded that venting the trapped air in a wet system can decrease water delivery time, reduce alarm ring delay, reduce water flow alarm cyclic ringing, and reduce corrosion activity. Other changes provide more flexible options for sprinkler design: A new protection scheme for exposed bay plastics in racks has been added to Chapter 17, in response to the potential for serious fires. New language added to Chapter 8 based on studies done by the Fire Protection Research Foundation allows sprinklers to be omitted above certain cloud ceiling configurations. Conversions to metric have switched from an exact conversion into an approximate conversion to make the Standard more usable and cost effective on a global scale. A new provision requires listed window sprinklers to be used where glazing assemblies are used as an alternative to fire-resistance-rated construction. Revisions in Chapter 9 address the use of concrete anchors An alternative storage protection scheme has been added for certain storage arrangements, similar to the Scheme A allowance in NFPA 30: Flammable and Combustible Liquids Code. Gain the edge in sprinkler protection to prevent fire deaths and property loss. NFPA 13: Standard for the Installation of Sprinkler Systems advances how sprinkler system designers, installers, maintainers, and AHJs can safeguard people and property against fire. Improve automatic fire sprinkler effectiveness and avoid errors using the new research-based 2016 edition of NFPA 13: Installation of Sprinkler Systems
The following editions for this book are also available...This book also exists in the following packages...Subscription InformationMADCAD.com NFPA subscriptions are annual and access is concurrency based (number of people that can access the subscription at any given time).
Some features of MADCAD.com NFPA Subscriptions are:
- Floating concurrency model: Set your concurrency level and share your NFPA Subscriptions among your offices enterprise-wide.
- Immediate Access: As soon as the transaction is completed, your NFPA Subscription will be ready for access.
For any further information on MADCAD.com NFPA Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About NFPAThe mission of the international nonprofit NFPA, established in 1896, is to reduce the worldwide burden of fire and other hazards on the quality of life by providing and advocating consensus codes and standards, research, training, and education.
The world's leading advocate of fire prevention and an authoritative source on public safety, NFPA develops, publishes, and disseminates more than 300 consensus codes and standards intended to minimize the possibility and effects of fire and other risks.
NFPA membership totals more than 70,000 individuals around the world
|
GROUPS
|