Already a subscriber?
MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?
BS EN IEC 60809:2015+A2:2018 Lamps for road vehicles. Dimensional, electrical and luminous requirements, 2018
- undefined
- Foreword
- Endorsement notice
- Annex ZA (normative) Normative references to international publications with their corresponding European publications [Go to Page]
- English [Go to Page]
- CONTENTS
- FOREWORD
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Requirements and test conditions for filament lamps [Go to Page]
- 4.1 General requirements
- 4.2 Lamp marking
- 4.3 Bulbs
- 4.4 Colour [Go to Page]
- 4.4.1 Colour of light
- 4.4.2 Colour endurance
- 4.4.3 Coated bulb
- 4.5 Lamp dimensions
- 4.6 Caps and bases
- 4.7 Initial electrical and luminous requirements
- 4.8 Check on optical quality [Go to Page]
- 4.8.1 General
- 4.8.2 12 V lamps emitting white light
- 4.8.3 6 V and 24 V lamps emitting white light
- 4.8.4 Lamps emitting selective-yellow light
- 4.9 UV radiation
- 4.10 Standard (étalon) filament lamps
- 4.11 Non-replaceable filament lamps [Go to Page]
- 4.11.1 General
- 4.11.2 Fixation
- 4.11.3 Lifetime
- 4.11.4 Colour endurance
- 4.11.5 Luminous flux and colour maintenance
- 4.11.6 Vibration and shock resistance
- Tables [Go to Page]
- Table 1 – Lifetime of non-replaceable filament lamps
- 5 Requirements and test conditions for discharge lamps [Go to Page]
- 5.1 General requirements
- 5.2 Lamp marking
- 5.3 Bulbs
- 5.4 Caps
- 5.5 Position and dimensions of electrodes, arc and black stripes [Go to Page]
- 5.5.1 Measurements
- 5.5.2 Electrodes
- 5.5.3 Arc
- 5.5.4 Black stripes
- 5.6 Starting, run-up and hot-restrike characteristics [Go to Page]
- 5.6.1 Starting
- 5.6.2 Run-up
- 5.6.3 Hot-restrike
- 5.6.4 Compliance
- 5.7 Electrical and photometric characteristics [Go to Page]
- 5.7.1 Voltage and wattage
- 5.7.2 Luminous flux
- 5.7.3 Compliance
- 5.8 Colour
- 5.9 UV radiation
- 5.10 Standard (étalon) discharge lamps
- 6 Requirements and test conditions for LED light sources [Go to Page]
- 6.1 General requirements
- 6.2 Light source marking
- Table 2 – Spectral weighting function
- 6.3 Optical surfaces
- 6.4 Colour of light
- 6.5 Lamp dimensions
- 6.6 Caps and bases
- 6.7 Initial electrical and photometrical requirements
- 6.8 Red content
- 6.9 UV radiation
- 6.10 Standard (étalon) light sources
- 7 Sampling and conditions of compliance
- 8 Lamp data sheets [Go to Page]
- 8.1 General
- 8.2 List of specific lamp types
- Annexes [Go to Page]
- Annex A (normative) Filament shape, length and position [Go to Page]
- A.1 General
- A.2 Filaments shown as points
- A.3 Line filaments
- A.4 Coiled-coil filaments
- A.5 Extreme filament turns
- A.6 Filament extremities [Go to Page]
- A.6.1 General
- A.6.2 Axial filaments
- A.6.3 Transverse filaments
- A.7 Determination of filament length
- A.8 Filament offsets
- A.9 Lateral deviation
- A.10 Filament location check system (box system)
- Figures [Go to Page]
- Figure A.1 – Determination of apexes, filament length and filament offsets (A and B)
- Figure A.2 – Determination of filament centre
- Figure A.3 – Determination of lateral deviations (A and B) and tolerance on the light centre length (C)
- Annex B (normative) Measurement method of the colour of filament lamps [Go to Page]
- B.1 General
- B.2 Colour
- B.3 Measuring directions [Go to Page]
- B.3.1 General
- B.3.2 Filament lamps used in headlamps
- B.3.3 Filament lamps used in light signalling devices
- Figure B.1 – Positions of the colorimetric receiver when measuring lamps used in headlamps
- Figure B.2 – Positions of the colorimetric receiver when measuring lamps used in light signalling devices
- Annex C (normative) Test conditions for electrical and luminous characteristics [Go to Page]
- C.1 Filament lamps [Go to Page]
- C.1.1 Ageing
- C.1.2 Test conditions
- C.1.3 Electrical instrumentation
- C.1.4 Photometry
- C.2 LED light sources [Go to Page]
- C.2.1 Test conditions
- C.2.2 Luminous flux
- C.2.3 Normalized luminous intensity
- C.2.4 Colour
- C.2.5 Power consumption
- Table C.1 – Luminous flux tolerance limits
- Annex D (normative) Method of measuring internal elements of R2 lamps [Go to Page]
- D.1 General test conditions [Go to Page]
- D.1.1 Measurement position
- D.1.2 Ageing
- D.1.3 Test condition
- D.2 Reference axis, reference plane and planes for measurements [Go to Page]
- D.2.1 Reference axis
- D.2.2 Reference plane
- D.2.3 Plane V-V
- D.2.4 Plane H-H
- D.2.5 Plane X-X
- D.2.6 Plane Y1-Y1
- D.2.7 Plane Y2-Y2
- D.3 Viewing directions (see Figure D.1) [Go to Page]
- D.3.1 Viewing direction 1
- D.3.2 Viewing direction 2
- D.3.3 Viewing direction 3
- D.4 Measuring points (MP)
- D.5 Dimensions to be measured
- Table D.1 – Dimensions to be measured for R2 lamps
- Figure D.1 – Viewing directions, seen from the top of the lamp
- Figure D.2 – Position of measuring points of R2 lamps
- Annex E (normative) Method of measuring internal elements of H4 and HS1 lamps [Go to Page]
- E.1 General test conditions [Go to Page]
- E.1.1 Measurement position
- E.1.2 Ageing
- E.1.3 Test condition
- E.2 Reference axis, reference plane and planes for measurements [Go to Page]
- E.2.1 Reference axis
- E.2.2 Reference plane
- E.2.3 Plane V-V
- E.2.4 Plane H-H
- E.2.5 Plane X-X
- E.2.6 Plane Y1-Y1
- E.2.7 Plane Y2-Y2
- E.2.8 Plane Y3-Y3
- E.2.9 Plane Y4-Y4
- E.2.10 Plane Y5-Y5
- E.3 Viewing directions (see Figure E.1) [Go to Page]
- E.3.1 Viewing direction 1
- E.3.2 Viewing direction 2
- E.3.3 Viewing direction 3
- E.4 Measuring points (MP) [Go to Page]
- E.4.1 Shield and filaments (see Figure E.2)
- E.4.2 Top obscuration (see Figure E.3)
- E.5 Dimensions to be measured
- Figure E.1 – Viewing directions, seen from the top of the lamp
- Table E.1 – Dimensions to be measured for H4 and HS1 lamps
- Figure E.2 – Position of measuring points of H4 and HS1 lamps
- Figure E.3 – Top obscuration
- Annex F (normative) Method of measuring internal elements of HB1 lamps [Go to Page]
- F.1 General test conditions [Go to Page]
- F.1.1 Measurement position
- F.1.2 Ageing
- F.1.3 Test condition
- F.2 Dipped beam filament location [Go to Page]
- F.2.1 Horizontal location
- F.2.2 Vertical location
- F.2.3 Axial location
- F.3 Main beam filament location [Go to Page]
- F.3.1 Horizontal location
- F.3.2 Vertical location
- F.3.3 Axial location
- Figure F.1 – Side view, view from 3ab
- Figure F.2 – Plan view, view from 4a
- Annex G (informative) Optical set-up for the measurement of the position and form of the arcand of the position of the electrodes of discharge lamps
- Figure G.1 – Optical system
- Annex H (normative) Measurement method of electrical and photometric characteristics of discharge lamps [Go to Page]
- H.1 General
- H.2 Ballast
- H.3 Burning position
- H.4 Ageing
- H.5 Supply voltage
- H.6 Starting test
- H.7 Run-up test
- H.8 Hot restrike test
- H.9 Electrical and photometric test
- H.10 Colour
- Annex I (informative) Overview of lamp types and their applications
- Annex J (normative) Test conditions for colour endurance measurements [Go to Page]
- J.1 General
- J.2 Calibration and ageing
- Table J.1 – Applicable switching modes
- Table J.2 – Applicable boxes of the test racks [Go to Page]
- J.3 Test voltage
- J.4 Operating position
- J.5 Test rack
- J.6 Operating cycles
- Figure J.1 – Side view of box
- Figure J.2 – Front view of box
- Table J.3 – Dimensions of the applicable boxes and the relative position of the centre of the filament
- Figure J.3 – Temperature in the climate chamber during one operating cycle
- Figure J.4 – Relative humidity in the climate chamber during one operating cycle
- Table J.4 – Timing during one operating cycle
- Figure J.5 – Switching modes of filament lamps for intermittent operationduring one operating cycle
- Figure J.6 – Switching modes of filament lamps for intermittent and continuous operation during one operating cycle
- Table J.5 – Switching modes of the filament lamps [Go to Page]
- J.7 Closure
- Figure J.7 – Switching modes of filament lamps for continuous operation during one operating cycle
- Figure J.8 – Switching modes of filament lamps for intermittent and continuous operation during one operating cycle [Go to Page]