14/30243471 DC BS ISO 15082. Road vehicles. Tests for rigid plastic safety glazing materials, 2014
- file.pdf [Go to Page]
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Test conditions
- 5 Conditioning of test specimens
- 6 Application of tests
- 7 Optical properties test
- 8 Head-form/fragmentation test [Go to Page]
- 8.1 Principle
- 8.2 Apparatus
- 8.3 Test specimens
- 8.4 Procedure
- 8.5 Expression of results
- 9 Head-form test with deceleration measurement [Go to Page]
- 9.1 Principle
- 9.2 Test conditions
- 9.3 Conditioning of test pieces
- 9.4.1 Head-form weight: head-form (as shown in Figure 4 for data transmission via co-axial (BNC) cables) with total mass of 10.0 kg +0.2/-0.0 kg, which allows the simultaneous determination of HIC-values. The components of the head-form according to ... [Go to Page]
- 9.4.2 Measuring device – for recording and evaluation of the measured deceleration curves ax(t), ay(t) and az(t), transmitted from the head-form acceleration gauges via cables or wireless: acceleration gauges, measuring and recording instruments accor...
- 9.4.3 Supporting fixture for testing flat test specimens, as shown in Figure 5. The fixture is composed of two steel frames, with machined edges, 50 mm wide, fitting one over the other and faced with rubber gaskets about 3 mm thick, and 50 mm +1/-0 mm...
- 9.4.4 Supporting fixture for testing complete panes: The support shall consist of a rigid piece corresponding to the shape of the pane so that the head-form weight faces the internal surface. The pane shall be clamped to the supporting structure by me...
- 9.4.5 Equipment to calibrate the head-form [Go to Page]
- 9.4.5.1 Drop appliance which must allow drop heights between 50 mm and 254 mm to be adjusted exactly to within 1 mm. A guide system is not necessary for these small drop heights.
- 9.4.5.2 Impact plate made of steel, dimensions 600 mm x 600 mm, minimum thickness 50 mm, flatness tolerance t = 0.05 mm, determined in accordance with ISO 1101.
- 9.5 Calibration procedure and adjustment of the head-form
- 9.6 Test Pieces: Flat test specimens (1170 mm +0/-2 mm x 570 mm +0/-2 mm) or complete panes shall be subjected to testing.
- 9.7 Test Procedure: In case of flat test specimens, fix the specimen in the supporting frames (Paragraph 9.4.3). In case of tests on complete panes, clamp the pane to a support which has a shape corresponding to the pane (Paragraph 9.4.4).
- 9.8 Evaluation
- 9.9 Expression of results
- Remarks
- Material
- 10 227g ball test [Go to Page]
- 10.1.1 Principle
- 10.1.2 Apparatus
- 10.1.3 Test specimens
- 10.1.4 Procedure
- 10.1.5 Expression of results
- 10.2 2260 g ball test [Go to Page]
- 10.2.1 Principle
- 10.2.2 Apparatus
- 10.2.3 Test specimens
- 10.2.4 Procedure
- 10.2.5 Expression of results
- 11 Abrasion resistance test [Go to Page]
- 11.1 Principle
- 11.2 Abrasion resistance under dry conditions [Go to Page]
- 11.2.1 Apparatus
- 11.3 Test specimens
- 11.4 Standardization of Abrading Wheels
- 11.5 Procedure
- 12.1 Principle
- 12.2. Apparatus
- 12.3. Test specimens
- 12.4. Procedure
- 13 Chemical resistance test [Go to Page]
- 13.1 Principle
- 13.2 Chemical agents to be used
- 13.3 Test specimens
- 13.4 Test procedure [Go to Page]
- 13.5 Expression of results
- 14 Resistance to simulated weathering test [Go to Page]
- 14.1 Principle
- 14.2. Exposure apparatus
- 14.3 Test specimens
- 14.4 Procedure
- 14.5 Evaluation
- 14.6 Expression of results
- 14.7 Report of test parameters
- 15 Fire Resistance Test [Go to Page]
- 15.1 Principle
- 15.2 Apparatus
- 15.3 Test specimens
- 15.4 Test procedure
- 15.5 Expression of results [Go to Page]