Already a subscriber? 

MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?

BS ISO 23420:2021 Microbeam analysis. Analytical electron microscopy. Method for the determination of energy resolution for electron energy loss spectrum analysis, 2021
- National foreword
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Symbols and abbreviated terms
- 5 Definition of the energy resolution
- 6 Reference materials and energy determination [Go to Page]
- 6.1 General
- 6.2 Materials selection for energy scale calibration
- 6.3 Binding energy measurement of graphite in the XPS
- 7 Measurement procedure and energy resolution determination [Go to Page]
- 7.1 General
- 7.2 Predetermination of binding energy [Go to Page]
- 7.2.1 Obtain graphite and the other reference sample
- 7.2.2 Measure C1s of graphite by using the XPS
- 7.3 Setup of the S/TEM and the EELS, and sample setting
- 7.4 First energy step, δE1, calibration [Go to Page]
- 7.4.1 EELS acquisition set-up
- 7.4.2 Determining the EELS first energy step, δE1
- 7.4.3 Acquisition of carbon K-edge EEL spectrum
- 7.4.4 Calculate calibrated energy step δE1C
- 7.5 Measurement of peak close to the zero-loss peak, ECZLP, for the other reference sample using energy step δE1 [Go to Page]
- 7.5.1 EEL spectrum acquisition of the second reference sample using energy step δE1
- 7.5.2 Obtain the value for CH2 between the zero-loss peak and the peak ECZLP
- 7.5.3 Calculate the peak ECZLP energy
- 7.6 Second energy step, δE2, calibration [Go to Page]
- 7.6.1 Determining the EELS second energy step, δE2
- 7.6.2 Acquire ECZLP EEL spectrum
- 7.6.3 Obtain the value for CH3 between the zero-loss peak and peak ECZLP
- 7.6.4 Calculate calibrated energy step δE2C
- 7.7 Determining the calibrated EEL spectrometer energy resolution, ΔE [Go to Page]
- 7.7.1 Acquisition of a ZLP EEL spectrum
- 7.7.2 Obtain the value for CH4 for the zero-loss peak
- 7.7.3 Calculate EEL spectrometer energy resolution, ΔE
- 7.8 Record items
- 8 Uncertainty for the measurement result of energy resolution
- Annex A (informative) Example of measurement procedure for energy resolution determination
- Annex B (informative) Correspondence between energy values of XPS C1s and EELS carbon K edge
- Bibliography [Go to Page]