NFPA 851: Recommended Practice for Fire Protection for Hydroelectric Generating Plants, 2000
- Chapter 1 Introduction [Go to Page]
- 1-1 Scope.
- 1-2 Purpose.
- 1-3 Application.
- 1-4 Definitions.
- 1-5 Units.
- Chapter 2 Fire Risk Control Program [Go to Page]
- 2-1 General.
- 2-2 Management Policy and Direction.
- 2-3 Fire Risk Control Program.
- 2-4 Fire Protection Program.
- Chapter 3 General Plant Design [Go to Page]
- 3-1 Fire Risk Evaluation.
- 3-2 Plant Arrangement.
- 3-3 Life Safety.
- 3-4 Building Construction Materials.
- 3-5 Smoke and Heat Venting, Heating, Ventilating, and Air- Conditioning.
- 3-6 Drainage.
- 3-7 Emergency Lighting.
- 3-8 Lightning Protection.
- Chapter 4 General Fire Protection Systems and Equipment [Go to Page]
- 4-1 General Considerations.
- 4-2 Water Supply.
- 4-3 Valve Supervision.
- 4-4 Supply Mains and Hydrants.
- 4-5 Standpipe and Hose Systems.
- 4-6 Portable Fire Extinguishers.
- 4-7 Fire Suppression Systems and Equipment — General Requirements.
- 4-8 Fire Signaling Systems.
- 4-9 Unattended Plants.
- Chapter 5 Identification and Protection of Hazards [Go to Page]
- 5-1 General.
- 5-2 Turbine-Generator Hydraulic Control and Lubricating Oil Systems.
- 5-3 Generator Pit and Windings.
- 5-4 Control, Computer, and Communication Rooms.
- 5-5 Cable Concentrations.
- 5-6 Cable Tunnels.
- 5-7 Transformers.
- 5-8 Indoor Oil-Filled Electrical Equipment.
- 5-9 Battery Rooms.
- 5-10 Switchgear and Relay Rooms.
- 5-11 Emergency Generators.
- 5-12 Air Compressors.
- 5-13 Hydraulic Systems for Gate and Valve Operators.
- 5-14 Fire Pumps.
- 5-15 Storage Rooms, Offices, and Shops.
- 5-16 Warehouses.
- 5-17 Auxiliary Heating.
- 5-18 Garages.
- Chapter 6 Fire Protection for the Construction Site [Go to Page]
- 6-1 Introduction.
- 6-2 Administration.
- 6-3 Site Clearing, Excavation, and Tunneling.
- 6-4 Construction Warehouses, Shops, Offices, and Construction Camps.
- 6-5 Construction Site Laydown Areas.
- 6-6 Temporary Construction Materials.
- 6-7 Underground Mains, Hydrants, and Water Supplies.
- 6-8 Fire Suppression Systems and Equipment.
- Chapter 7 Referenced Publications [Go to Page]
- 7-1 The following documents or portions thereof are referenced within this recommended practice ...
- Appendix A Explanatory Material
- Appendix B Sample Fire Report
- Appendix C Referenced Publications
- Index [Go to Page]