ASTM F1596-00
Historical Standard: ASTM F1596-00 Standard Practice for Exposure of Membrane Switches to Temperature and Relative Humidity
SUPERSEDED (see Active link, below)
ASTM F1596
1. Scope
1.1 This practice covers a procedure for temperature and humidity cycling of membrane switches.
1.2 This practice is designed to determine changes induced by temperature and humidity.
1.3 This practice is not intended to be a thermal shock procedure; a gradual ramp rate between conditions is required.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
F1661 Test Method for Determining the Contact Bounce Time of a Membrane Switch
F1662 Test Method for Verifying the Specified Dielectric Withstand Voltage and Determining the Dielectric Breakdown Voltage of a Membrane Switch
F1663 Test Method for Determining the Capacitance of a Membrane Switch
F1680 Test Method for Determining Circuit Resistance of a Membrane Switch
F1689 Test Method for Determining the Insulation Resistance of a Membrane Switch
F2592 Test Method for Measuring the Force-Displacement of a Membrane Switch
Keywords
membrane switch; relative humidity (RH); temperature;
ICS Code
ICS Number Code 31.220.20 (Switches)
DOI: 10.1520/F1596-00
ASTM International is a member of CrossRef.